Series 1075U
Endura-Shield II
Generic Type
Aliphatic Acrylic Polyurethane
Common Usage
A coating highly resistant to abrasion, wet conditions, corrosive fumes and exterior weathering. High build quality combines with project specific primers for two-coat, labor saving systems. Contains a blend of ultraviolet (UV) light absorbers for enhanced color and gloss retention. Fast curing options are available; see Curing Time below. Product has some applications as a direct to metal finish. Contact your Tnemec representative for more details. NOT FOR IMMERSION SERVICE.
Special Qualifications
Series 1075U meets the requirements of SSPC-36 (level 3) Paint Standard.
View more product detailsProduct Data Sheets
- English_Series_1075U_Endura_Shield_Ii_pds.pdf
- French_Series_1075U_Endura_Shield_Ii_pds.pdf
- Spanish_Series_1075U_Endura_Shield_Ii_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
-
This product is available in 504 colors.
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
Primers
Steel: Series 1, 20, FC20, 27, 27WB, 66, L69, L69F, N69, N69F, V69, V69F, 90-97, 91-H₂O, 94-H₂O, 104, 118, 135, L140, L140F, N140, N140F, V140, V140F, 141, 161, 394, V530. Note: Series 118 is typically used to overcoat, sound, existing coating systems. See product data sheet for more information.
Galvanized Steel and Non-Ferrous Metal: Series 66, L69, N69, V69, 135, 1224. Note: For special galvanized surface preparation instructions, consult the latest version of Tnemec Technical Bulletin 10-78.
Concrete: Series 66, L69, L69F, N69, N69F, 104, 161
CMU: 54, 130. Intermediate coat required.
Note: Before topcoating with Series 1075U, Series V530 exterior exposed for more than 24 hours must first be scarified or receive an intermediate coat of Tnemec polyamide epoxy. Recoat windows for other primers may apply. See those data sheets for additional information.
Recommended DFT
2.0 to 5.0 mils (50 to 125 microns) per coat. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
HAPS
Unthinned | Maximum 15% No. 39 Thin.) | Max 15% No. 42 Thin.) | Max 15% No. 48 Thin.) | Max 15 No. 56 Thin.) |
---|---|---|---|---|
0.0 lbs/gal | 0.0 lbs/gal | 0.0 lbs/gal | 0.0 lbs/gal | 0.0 lbs/gal |
Curing Time
Temperature | To Handle | To Recoat | Resist Moisture |
---|---|---|---|
95°F (35°C) | 4 hours | 5 hours | 3 hours |
75°F (24°C) | 6 hours | 8 hours | 5 hours |
55°F (13°C) | 12 hours | 16 hours | 9 hours |
35°F (2°C) | 36 hours | 48 hours | 20 hours |
Curing time varies with surface temperature, air movement, humidity and film thickness. If coating is exposed to moisture before the applicable cure parameters are met, dull, flat or spotty appearing areas may develop. Note: For faster curing and low-temperature applications, add No. 44-710 Urethane Accelerator; see separate product data sheet. Contact Tnemec Technical Services for force curing times and temperatures.
Volatile Organic Compounds
EPA Method 24 †
Unthinned | Maximum 15% No. 39 Thin.) | Max 15% No. 42 Thin.) | Max 15% No. 48 Thin.) | Max 15 No. 56 Thin.) |
---|---|---|---|---|
2.16 lbs/gal (258 g/l) | 2.70 lbs/gal (323 g/l) | 2.75 lbs/gal (330 g/l) | 2.83 lbs/gal (339 g/l) | 2.27 lbs/gal (271 g/l) |
Volume Solids
71 ± 2.0% (mixed) †
Theoretical Coverage
1,132 mil sq ft/gal (27.8 m²/L at 25 microns). See APPLICATION for coverage rates. †
Finish
Semi-gloss
Number of Components
Two: Part A and Part B
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep