Series 142
Epoxoline
Generic Type
Glass Flake Reinforced Modified Polyamine Epoxy
Common Usage
Abrasion resistant, high solids, epoxy coating which offers high-build edge protection and excellent corrosion resistance. Contains glass flake and aluminum oxide for improved film integrity. For use on the interior and exterior of steel or concrete tanks, pipes, and other heavy-duty equipment in industrial service.
View more product detailsContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Surfacer/Filler/Patcher
Series 215, 217, 218
Theoretical Coverage
1,315 mil sq ft/gal (32.2 m²/L at 25 microns). See APPLICATION for coverage rates. †
Number of Components
Two: Part A (amine) and Part B (epoxy)
Topcoats
Exterior: Series 73, 290, 1028, 1029, 1074, 1074U, 1075, 1075U. Note: The following maximum recoat time applies when using Series 73, 290, 1074, 1074U, 1075, 1075U: fourteen (14) days. If this time limit is exceeded, Series 142 must be uniformly scarified prior to topcoating.
Recommended DFT
8.0 to 20.0 mils (205 to 500 microns) in one coat. Note: Thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
HAPS
Unthinned: 1.27 lbs/gal solids
Thinned 5% (No. 4 Thinner): 1.31 lbs/gal solids
Thinned 10% (No. 4 Thinner): 1.36 lbs/gal solids
Volume Solids
82% ± 2.0% (mixed) †
Volatile Organic Compounds
EPA Method 24
Unthinned: 1.28 lbs/gallon (153 grams/litre)
Thinned 5% (No. 4 Thinner): 1.55 lbs/gallon (186 grams/litre)
Thinned 5% (No. 60 Thinner): 1.55 lbs/gallon (186 grams/litre)
Thinned 10% (No. 4 Thinner): 1.78 lbs/gallon (214 grams/litre)
Thinned 10% (No. 60 Thinner): 1.74 lbs/gallon (208 grams/litre)†
Curing Time
Temperature | To Handle | To Topcoat | Immersion |
---|---|---|---|
75°F (24°C) | 6 hours | 9 hours ‡ | 7 days |
35°F (0°C) | 64 hours | 72 hours ‡ | 30 days |
Curing time varies with surface temperature, air movement, humidity and film thickness. ‡Note: Specific application requirements, including cure schedule and environmental conditions, must be followed when topcoating Series 142. Contact Tnemec Technical Service for detailed instructions. Note: For overlaps, tie-ins, and touch-ups, maximum recoat time with itself is seven days.
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep