Series 972
Aerolon
Generic Type
Fluid-applied acrylic insulation coating
Common Usage
An innovative anti-condensation coating specifically designed for harsh marine environments. Ideal for reducing or eliminating condensation on bulkheads, overheads, tanks, pipes, ductwork, and other areas within marine vessels. This unique, water-based formulation contains a hydrophobic resin and particle blend that produces a durable, water-resistant system with excellent adhesion and durability. Part of a corrosion-resistant coating system that reduces condensation and issues associated with corrosion under insulation (CUI). Coating film contains biocides that aid in the prevention of mold and mildew growth.
Special Qualifications
Thermal Conductivity (ASTM C518 at 77°F): 0.0392 W/m-°K or 0.2718 BTU-in/ft²-hr-°F (R value at one inch equals 3.7)
View more product detailsContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Recommended DFT
30.0 to 60.0 mils (762 to 1524 microns) per coat.
Thermal Efficiency: 50 to 250 mils (1270 to 6350 microns)
Thermal Break: 80 to 100 mils (2032 to 2540 microns)
Personal Protection: 40 to 60 mils (1016 to 1254 microns)
Anti-Condensation: 100 to 250 mils (2540 to 6350 microns)
Note: Thickness recommendations will vary depending on specific project requirements and environmental conditions. Contact your Tnemec representative for more information. Note: Multiple coats may be required, please contact your Tnemec Representative for film thickness recommendations.
Curing Time
Temperature | To Touch | To Handle | To Recoat† | To Topcoat |
---|---|---|---|---|
95°F (35°C) | 45 minutes | 8 hours | 9 hours | 12 hours |
75°F (24°C) | 2 hours | 16 hours | 18 hours | 24 hours |
45°F (7°C) | 4 hours | 24 hours | 28 hours | 36 hours |
†Recoat times listed are with itself. Curing time varies with surface temperature, air movement, humidity and film thickness.
Volatile Organic Compounds
0.05 lb/gallon (6.04 grams/litre) †
HAPS
0 lb/gal solids
Theoretical Coverage
1,219 mil sq ft/gal (30.0 m²/L at 25 microns). See APPLICATION for coverage rates. †
Number of Components
One
Primers
Steel: Series 1224 or approved epoxy primer
Aluminum & Non-Ferrous Metals: Self-priming
Note: Contact your Tnemec representative for additional information.
Finish
Matte
Volume Solids
72 ± 2.0% (mixed) †
Topcoats
Contact your Tnemec representative for more information.
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep