Series FC20
Pota-Pox (Fast Cure)
This product has been discontinued. Please contact your local sales representative for further assistance.
Generic Type
Polyamide Epoxy
Common Usage
Fast-curing protective coating for use in steel and concrete structures. Contact your Tnemec representative for other systems and additional information on potential uses.
Special Qualifications
Certified by NSF International in accordance with ANSI/NSF Std. 61 for use on the interior of potable water storage tanks and reservoirs of 6,000 gallons (22,710 L) capacity or greater. Reference Tnemec's certified product listing at www.nsf.org for details on the maximum allowable DFT.
Conforms to AWWA D 102 Inside Systems No. 1 and No. 2. Contact your Tnemec representative for approved systems and additional information on potential uses.
Curing Time
Temperature | To Touch | To Handle | To Recoat | Immersion |
---|---|---|---|---|
75°F (24°C) | 1 hour | 2 hours | 3 hours | 6 days |
65°F (18°C) | 2 hours | 4 hours | 5-6 hours | 8 days |
55°F (13°C) | 3-4 hours | 6-8 hours | 10-12 hours | 12 days |
45°F (7°C) | 6-7 hours | 12-14 hours | 16-18 hours | 20 days |
35°F (2°C) | 8-10 hours | 16-18 hours | 20-22 hours | 25 days |
Curing time varies with surface temperature, air movement, humidity and film thickness.
Volatile Organic Compounds
Unthinned: 2.94 lbs/gallon (352 grams/litre)
Thinned 10%: 3.30 lbs/gallon (395 grams/litre) †
Surfacer/Filler/Patcher
Series 215
Recommended DFT
2.0 to 6.0 mils (50 to 150 microns) per coat. Note: Dry film thickness that exceeds published recommendations but is in compliance with SSPC PA-2 and ANSI/NSF Std. 61 certifications, is acceptable. Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Volume Solids
58.0 ± 2.0% (mixed) †
Colors
1211 Red, 1255 Beige, 00WH White, 15BL Tank White, 39BL Delft Blue.
Note: Epoxies chalk with extended exposure to sunlight. Lack of ventilation, incomplete mixing, miscatalyzation or the use of heaters that emit carbon dioxide and carbon monoxide during application and initial stages of curing may cause yellowing to occur.
Theoretical Coverage
930 mil sq ft/gal (22.8 m²/L at 25 microns). See APPLICATION for coverage rates. †
Topcoats
Interior: Series 20, FC20, 22, 141, N140, N140F, 264, 265
Exterior: Series 20, FC20, 22, 27WB, 30, 66, L69, L69F, N69, N69F, V69, V69F, 72, 73, 104, 118, N140, N140F, V140, V140F, 141, 161, 700, V700, 701, V701, 1026, 1028, 1029, 1074, 1074U, 1075, 1075U, 1094, 1095, 1096, 1224. Note: When topcoating with Series 700, V700, 701 or V701, an intermediate coat of Series 73, 1075, 1075U, 1095 or 1096 is required. Note: A maximum recoat time may apply depending on the topcoat specified.
Number of Components
Two: Part A and Part B